Cette publication ne fait pas partie de la bibliothèque YouScribe
Elle est disponible uniquement à l'achat (la librairie de YouScribe)
Achetez pour : 137,14 € Lire un extrait

Téléchargement

Format(s) : PDF

sans DRM

Implantable Cardioverter Defibrillator Stored ECGs

De
0 page

Implantable Cardioverter Defibrillator Stored ECGs instructs the reader on the appropriate and optimal reading of device diagnostics in clinical practice using a format developed around low text volume, charts, and practical (hands-on) protocols that can be used directly during ICD follow-up. This concise didactic reference book provides clinical information via the use of images to illustrate specific diagnostic features in defibrillator therapy. The first part consists of chapters on defibrillator diagnostics, followed by case-based presentations with images, actual patient histories and a summary paragraph. All common and some rarer situations are covered.

Voir plus Voir moins
Contents
Foreword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . .
Acknowledgements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.
2.
3.
Diagnostics and Therapy by the ICD: Better than the Cardiologist?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Historical Perspective of Diagnostic Information in ICDs ..................... The Diagnosis of Ventricular Tachycardia: A Continuing Story with a Happy End?........................................................................................ References.......................................................................................................
Rhythm Classification by Arrhythmia Management Devices. . . . . . . .
Verification of Signals During Implantation............................................. Early Devices: Detection of Ventricular Fibrillation ................................ Rate-only Detection ...................................................................................... Detection Zones............................................................................................. Interval-based Discriminators ..................................................................... Dual-chamber Discrimination ..................................................................... The Atrioverter: Detection of Atrial Tachyarrhythmias .......................... Morphology-based Algorithms.................................................................... References.......................................................................................................
vii
ix
xi
1
1
2 5
7
8 9 10 11 12 13 17 18 20
Device Diagnostics: Interval Tables, Event Counters, Interval Plots, Markers, Electrograms, and New Features. . . . . . . . . . . . . . . . . . . . . . . .23
Interval Tables and Event Counters ........................................................... Electrograms .................................................................................................. Interval Plots (Tachograms) ........................................................................ Event Markers, Marker Channels™, Status Channel ............................... New Features.................................................................................................. Conclusion...................................................................................................... References.......................................................................................................
24 25 29 31 34 37 38
v
vi
4.
5.
6.
Contents
Understanding Stored Electrograms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrogram Sources ..................................................................................... Visual Analysis of Stored Electrograms ..................................................... Application of Information Blocks in Relation to Rate Branches ......... A Standardized Approach for Electrogram Analysis ............................... A Practical Approach to Analyze Electrograms........................................ References.......................................................................................................
A Practical Approach to Analyze Stored Electrograms. . . . . . . . . . . . .
Stored Electrograms in Single-chamber Devices ...................................... Stored Electrograms in Dual-chamber Devices ........................................
Clinical Case Studies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Early Devices.................................................................................................. Single Chamber Devices ............................................................................... Dual Chamber Devices ................................................................................. Resynchronization Devices .......................................................................... Atrial Management Devices ......................................................................... Interval Plots.................................................................................................. Challenging Surface Electrocardiograms ...................................................
39
39 41 46 50 51 51
55
58 58
59
60 66 82 115 131 138 165
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191
http://www.springer.com/9781846286797