Influence du mouvement des organes et des paramètres d acquisition sur la qualité de l image en scanographie : application à la détermination de la composition chimique des calculs rénaux, Influence of organs motion and of acquisition parameters on CT image quality : application to the renal stones chemical composition determination
336 pages
Français

Découvre YouScribe en t'inscrivant gratuitement

Je m'inscris

Influence du mouvement des organes et des paramètres d'acquisition sur la qualité de l'image en scanographie : application à la détermination de la composition chimique des calculs rénaux, Influence of organs motion and of acquisition parameters on CT image quality : application to the renal stones chemical composition determination

-

Découvre YouScribe en t'inscrivant gratuitement

Je m'inscris
Obtenez un accès à la bibliothèque pour le consulter en ligne
En savoir plus
336 pages
Français
Obtenez un accès à la bibliothèque pour le consulter en ligne
En savoir plus

Description

Sous la direction de Jacques Hubert
Thèse soutenue le 22 septembre 2008: Nancy 1
Malgré les nombreuses améliorations qu’a connu la scanographie au cours de ces vingt dernières années, la qualité des images scanographiques reste fortement influencée par le mouvement (volontaire ou involontaire) du patient. La scanographie étant une technique irradiante basée sur l’utilisation des Rayons X, il est impossible d’étudier l’influence du mouvement des organes sur la qualité de l’image en plaçant des sujets sains dans la machine puisque l’exposition non justifiée des personnes au rayonnement est interdite. Des fantômes doivent donc être utilisés pour quantifier la qualité des images. De nombreux fantômes permettant de quantifier la qualité de l’image existent dans le commerce, mais aucun n’est mobile, nous avons donc dû concevoir et fabriquer une plate-forme de mouvement permettant de simuler des mouvements physiologiques. Cette plate-forme nous a permis de montrer que l’influence du mouvement dépendait de la taille, de la forme et du contraste de l’objet étudié. Le mouvement peut engendrer une déformation de l’objet, un redimensionnement et à une modification de sa valeur d’atténuation moyenne. Le mouvement conduit donc à une perte d’information sur la localisation, sur la densité, sur le volume et sur la forme des objets qui ont bougé durant l’acquisition. Cette perte d’information est d’autant plus importante que l’amplitude et/ou la vitesse du mouvement sont élevées. L’utilisation de scanners de générations et de technologies différentes nous a également permis d’étudier l’influence des paramètres d’acquisition (pitch, kV, mAs, vitesse de rotation du tube…) sur la qualité de l’image avec ou sans mouvement. Cette étude a mis en évidence le fait que le choix de paramètres d’acquisition pertinents était primordial pour obtenir une image optimale. L’influence du mouvement sur la qualité de l’image n’est également pas la même en fonction des paramètres d’acquisition choisis. L’étude de l’influence du mouvement et celle des paramètres d’acquisition a ensuite été appliquée à la technique de détermination de la composition chimique des calculs rénaux en CT. Cette technique, basée sur les valeurs d’atténuation aux RX des calculs rénaux, permet théoriquement de caractériser la nature chimique du calcul afin de choisir rapidement le meilleur moyen de traitement possible (LEC, chirurgie…). Pour mener à bien cette étude nous avons collectés des calculs obtenus après interventions urologiques chez des patients. Une analyse morphoconstitutionnelle préalable nous a permis de connaître leur composition chimique. A l’aide de la plus grande série de calculs jamais publiée et d’un fantôme « gelée » développé au sein du laboratoire et respectant au mieux les conditions d’absorption et d’atténuation du rein, nous avons ainsi réussi à mettre en place un protocole permettant de déterminer, avec une précision de 95%, la nature chimique du composant majoritaire d’un calcul. Cette technique, dite de « double énergie », permet d’identifier chaque type de calcul en se basant sur les valeurs d’atténuation aux RX d’un calcul obtenues à 80 et à 120 kV.La technique de « double énergie » n’est malheureusement plus valable quand le fantôme est mis en mouvement. En effet le mouvement génère des artefacts qui engendrent une modification des valeurs d’atténuation des calculs. L’échelle de valeurs, obtenues sans mouvement, permettant d’identifier un calcul n’est alors plus utilisable. Notre technique de caractérisation des calculs purs est donc efficace si et seulement si aucun mouvement n’a lieu durant l’acquisition.
-Mouvements respiratoires
-Paramètres d’acquisition
Despite all the improvements known by the Computed Tomography (CT) during the last 20 years, the CT image quality remains heavily influenced by the voluntary or involuntary patient motion. Since the CT is an irradiating imaging modality based on X-rays, it is impossible to study the influence of the organs motion on the image quality by using healthy subjects. Indeed, the unjustified exposure to radiation is prohibited. Consequently, phantoms have to be used to quantify the image quality. Such phantoms are commercially available but none is mobile. We have so designed and built a dynamic platform allowing the simulation of organs motion. This platform allowed us to show that the influence of the motion on image quality depended on the size, the shape and the contrast of the studied object. The motion led to a deformation, a resizing, and to a decreasing of the CT attenuation values of the studied object. The more the speed and the amplitude of the motion were, the more the loss of the information about the object was. The use of CT scanners of different generations, different technologies and different builders allowed us to study the influence of CT acquisition parameters on the image quality with and without motion. This study has highlighted the fact that the choice of the right CT parameters (pitch, kV, mAs, gantry rotation time…) was very important on the determination of the image quality. The influence of theses parameters were not the same with and without motion applied during the acquisition. Once these results obtained, we have tried to develop a technique of determination of the chemical composition of renal stones in CT. This technique is based on-the CT-attenuation values of the renal stones. It allows to characterize rapidly the chemical composition of the renal stone into choose as quickly as possible the best diagnosis and the best treatment (surgery, NPLC…). With the largest number (n = 241) of stones so far described, to our knowledge and with a home made jelly phantom respecting the absorption and the X-ray attenuation of the kidney, we have develop a protocol allowing to determine the chemical nature of the major component of a stone, with a 95% precision. Our dual-energy method allows to identify each stone based on the CT-attenuation values obtained at 80 kV and at 120 kV. Sadly, this method is no more applicable when the phantom moves during the acquisition. Indeed the motion induces decreasing of CT-attenuations values and consequently the scale of values obtained with no motion is no more usable. Our characterization technique works only if absolutely no motion occurs during the acquisition.
Source: http://www.theses.fr/2008NAN10041/document

Informations

Publié par
Nombre de lectures 66
Langue Français
Poids de l'ouvrage 13 Mo

Extrait




AVERTISSEMENT

Ce document est le fruit d'un long travail approuvé par le
jury de soutenance et mis à disposition de l'ensemble de la
communauté universitaire élargie.

Il est soumis à la propriété intellectuelle de l'auteur. Ceci
implique une obligation de citation et de référencement lors
de l’utilisation de ce document.

Toute contrefaçon, plagiat, reproduction illicite encourt une
poursuite pénale.


➢ Contact SCD Nancy 1 : theses.sciences@scd.uhp-nancy.fr




LIENS


Code de la Propriété Intellectuelle. articles L 122. 4
Code de la Propriété Intellectuelle. articles L 335.2- L 335.10
http://www.cfcopies.com/V2/leg/leg_droi.php
http://www.culture.gouv.fr/culture/infos-pratiques/droits/protection.htm NANCY UNIVERSITE – UNIVERSITE HENRI POINCARE NANCY 1
Faculté de Médecine
ECOLE DOCTORALE BIOLOGIE – SANTE – ENVIRONNEMENT

N° attribué par la bibliothèque


THESE

Pour obtenir le grade de

DOCTEUR DE NANCY-UNIVERSITE, UNIVERSITE HENRI POINCARE NANCY 1

Spécialité : Bioingénierie

Présentée et soutenue publiquement

Par

Romain GROSJEAN

Le Lundi 22 Septembre 2008


INFLUENCE DU MOUVEMENT DES ORGANES ET DES PARAMETRES D ’ACQUISITION SUR LA
QUALITE DE L’IMAGE EN SCANOGRAPHIE ;
APPLICATION A LA DETERMINATION DE LA COMPOSITION CHIMIQUE DES CALCULS RENA.UX


Directeur de Thèse : Professeur Jacques HUBERT


JURY

Pr. Alain BLUM Professeur des Université – Praticien Hospitalier UHP Nancy
Dr. Patrick CLARYSSE Chargé de Recherche CNRS Inserm U630, Lyon
Dr. Michel DAUDON Praticien Hospitalier Hôpital Necker, Paris
Pr. Jacques FELBLINGER Professeur des Université – Praticien Hospitalier UHP Nancy
Pr. Jacques HUBERT Professeur des Université – Praticien Hospitalier UHP Nancy
Pr. Olivier TRAXER Professeur des Université – Praticien Hospitalier Hôpital Tenon, Paris

NANCY UNIVERSITE – UNIVERSITE HENRI POINCARE NANCY 1
Faculté de Médecine
ECOLE DOCTORALE BIOLOGIE – SANTE – ENVIRONNEMENT

N° attribué par la bibliothèque


THESE

Pour obtenir le grade de

DOCTEUR DE NANCY-UNIVERSITE, UNIVERSITE HENRI POINCARE NANCY 1

Spécialité : Bioingénierie

Présentée et soutenue publiquement

Par

Romain GROSJEAN

Le Lundi 22 Septembre 2008


INFLUENCE DU MOUVEMENT DES ORGANES ET DES PARAMETRES D ’ACQUISITION SUR LA
QUALITE DE L’IMAGE EN SCANOGRAPHI E;
APPLICATION A LA DETERMINATION DE LA COMPOSITION CHIMIQUE DES CALCULS RENAUX .


Directeur de Thèse : Professeur Jacques HUBERT


JURY

Pr. Alain BLUM Professeur des Université – Praticien Hospitalier UHP Nancy
Dr. Patrick CLARYSSE Chargé de Recherche CNRS Inserm U630, Lyon
Dr. Michel DAUDON Praticien Hospitalier Hôpital Necker, Paris
Pr. Jacques FELBLINGER Professeur des Université – Praticien Hospitalier UHP Nancy
Pr. Jacques HUBERT Professeur des Université – Praticien Hospitalier UHP Nancy
Pr. Olivier TRAXER Professeur des Université – Praticien Hospitalier Hôpital Tenon, Paris























À mes parents…


















« Mieux vaut avoir approximativement raison qu'avoir précisément tort. »

« Je veux pouvoir expliquer mes erreurs. C'est pourquoi je ne fais que des choses que je comprends. »

« Vous n'avez pas raison parce que d'autres sont d'accord avec vous.
Vous avez raison parce que vos faits sont exacts et que votre raisonnement est juste. »




Warren Buffett
1930-20??

  • Univers Univers
  • Ebooks Ebooks
  • Livres audio Livres audio
  • Presse Presse
  • Podcasts Podcasts
  • BD BD
  • Documents Documents