LYNXREN1.DOC v10/01 Page 1 of7 LynxREN– Setup of Hardwired Zone A step by step procedure on the Hardwired zoneThis Checklist procedure is This is what we’ll cover in this procedure… intended for all revisions of this product, based on the ‘Starting Wire the protection loop Revision’. If there are any Programming revision-specific changes, they Voice Vocabulary Indexwill be included at the end of Tech Notes!the document, sorted by Audio file(if available) revision. Please check the revision of your product before Video file(if available)proceeding – Call Technical Support if you cannot find the revision of your product. 1.Wire the Hardwired zone to terminals 6 and 7Diagram). (See 1.1. Make sure to wire the 2K resistor at the end of line. 1.1.1. Ifwiring a Normally Closed detector the resistor should be wired in series. 1.1.2. Ifwiring a Normally Open detector the resistor should Required partsfor this be wired in parallel. procedure: 2K resistor 2. (Optional)Wire the peripheral device, if used, to a separate power (included), contact (not supplyincluded) or 4-wire 2.1. A common ground is not needed in this caseperipheral device (not included). For the 4-wire 2.2. Refer to the peripheral device instructions and the power peripheral device a separate supply’s instruction for proper connections power supply will be 3. Enterprogram mode needed.The Lynx cannot 3.1. Press Installer code* + 8 + 0 + 0 supply auxiliary power.*Default installer code is 4112 4.Enter Zone Programming4.1. Press *56 (follow menus below)
LYNXREN1.DOC v10/01 Page2 of 7 These are the only screens that are A 01Zone Numberneeded to program a Hardwired Zone(s)b 00Zone TypeC 00Report Code F 00Delete Zone Parameter 1C 00Voice Descriptors 1D 00Descriptor 1 1E 00Descriptor 2 1F 00Descriptor 3 Screen and FunctionNotes Pressing 00 exits mode, upon which the prompt “56” A 01Zone Numberblinks, indicating the mode is inactive. Press [*] + any field number to go to that field. Enter the Zone number* to proram:*Possible Zone numbers: 01-41, 95, 96, 99Zone 01 comes ( up as default Zone 1 = hardwire Zones 2-25 = RF zones Zones 26-41 = Button zones Zones 95, 96, 99 = Panic zones Enter zone numbers as 2-diit entries. Press* (to go to the next screen) Or Press # to cancelour entrand oback to previous screen Or 00 = Exit Zone Programming mode Each zone must be assigned to a zone type, which b 00 Zone Typedefines the way in which the system responds to faults in that zone Enter the Zone Te* toro ram: *Possible Zone tes: 00-24 Te 00 comes uas default 00 = Not Usedor to delete a zone 01 = Entr/Exit #1 02 = Entr/Exit #2 03 = Perimeter 04 = Interior Follower 05 = Trouble Day/Alarm Night 06 = 24 Hr Silent 07 = 24 Hr Audible 08 = 24 Hr Aux
LYNXREN1.DOC v3 of 710/01 Page
09 = Fire w/verif 10 = Interior w/Dela 20 = Arm–Sta 21 = Arm–Awa 22 = Disarm 23 = No Alarm Response 24 = Silent Burglary Enter zone tpes as 2-di
it entries.
Press* (to go to the next screen) Or Press # to cancelour entrand oback to revious screen
C 00 Report code Enter the reort code for this zone
Even thouh oudon’t see the ‘ointer’, afterou enter two consecutive diits ouwill seeour two diit entr turn into one number in ‘hex’ formatSEE HEX LIST
 Hex List 00=0 10=A 01=1 11=B 02=2 12=C 03=3 13=D 04=4 14=E 05=5 15=F 06=6 07=7 08=8 09=9
L nxmoves digits…
ou automaticall
between the two
First diit of the reort code Second digit of the report code
À À C 00C 00
Each of these digits can range from 0 to F
See ExamlesOr Press* (to go to the next screen) Or Press # to cancelour entrand oback to
If this is Zone 1, the system skips to the VOICE DESCRIPTOR prompt
LYNXREN1.DOC v4 of 710/01 Page
previous screen
Example 1: Lynx is ‘pointing’ to the first report code and ifou entered “01” the first reort code would chane to “1” À C 10
Example 2: Lnx is ‘pointin’ to the second report code and ifou entered “11” the second reort code would change to “b” À C 1b FDelete ZoneParameter This screen onlcomes uif ouentered 00 as a zone te in the on theZone Te screenEnter a sinle diit 0-20 = keep existinnumber and proceed to VOICE DESCRIPTORrom t
1 or 2 =For non-RF zones,will delete all zone information.
If “1 or 2” is entered, the sstem will delete all zone information for this zone and return to the ZONE NUMBER prompt (A).
1CVoice Descriptor
Enter a single digit (0-1)
0 = skip to next zoneA 1 = enter descritor mode, takinou to the next screen. Then the existindescri tor for this zone will be announced throuh the speaker 1dDescriptor 1
Upon enterinthis screen the current descriptor will be heard through the speaker.
Each zone can have a voice descriptor of up to 3 words that will be announced whenever the system announces status for that zone.
If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to return to zone number prompt.
LYNXREN1.DOC v10/01 Page5 of 7
To chane the voice descritor… number ofEnter # +vocabular index2-di it first descritor word for this zone. 6 = accept word and advance to descriptor 2 descriptor 2 will be announced t word and advance to next zone8 = acce rom tA –entire zone descritor will be announced Press any other key to repeat the selected word.
For example, Enter # + 12 for the voice descri torof “Door”… 1d 12
1EDescriptor 2
Upon entering this screen the current descri torwill be heard throuh the seaker.
To chane the voice descritor… Enter [#] + 2-digit vocabulary index number of Second descriptor word for this zone. 6 = accet word and advance to descritor 3 descri tor3 will be announced 8 = accet word and advance to next zone (prompt A) – entire zone descriptor will be announced other kePress aneat the selected word.to re
For example, Enter # + 42 for the voice descriptor of “Window”… 1E 42
1FDescriptor 3
U onenterin thisscreen the current descriptor will be heard through the speaker.
To chane the voice descriptor… number ofvocabular index2-di itEnter # + Second descritor word for this zone. 6 or 8 = accept word and advance to next zone (prompt A) – entire zone descriptor will be announced to reeat the selected word.Press another ke
For example, Enter # + 42 for the voice descriptor of “Garage”… 1F 17
If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to return to zone number prompt.
If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to return to zone number prompt.
LYNXREN1.DOC v6 of 710/01 Page
Diagram(s)
00 ½ second pause A 01 ALARM 02 ATTIC B03 BABY 04 BACK 05 BASEMENT 06 BATHROOM 07 BEDROOM C08 CHECK D09 DEN 10 DETECTOR 11 DINING 12 DOOR E13 EMERGENCY F14 FIRE 15 FLOOR 16 FRONT
Voice Vocabulary Index
G17 GARAGE 18 GUNH19 HALL I20 INSIDE K21 KITCHEN L22 LAUNDRY 23 LIBRARY 24 LIVING M25 MAIN 26 MASTER 27 MESSAGE 28 MOTION O29 OFFICE P30 PATIO 31 POOL R32 ROOM
S33 SHED 34 SHOP 35 SIDE 36 SLIDING 37 SMOKE 38 STORAGE 39 SYSTEM U40 UPSTAIRS 41 UTILITY W42 WINDOW Y43 YARD Z44 ZONES 45 1 ST 46 2 ND 47 3 RD 70 Custom Word #1 71 Custom Word #2 72 Custom Word #3 73 Custom Word #4 74 Custom Word #5 99 Blank (for erasing a previously programmed word)
LYNXREN1.DOC v10/01 Page7 of 7
Tech Notes
Audio Narrative(s)Video Narrative(s)
If the EOLR is not at the end of the loop, the zone will not be properly supervised, and the system may not respond to an open circuit on the zone. Zone 1 is an EOLR supervised zone that supports both open circuit and closed circuit devices and has a response time of 350msec. Maximum zone resistance: 300 ohms, plus EOLR The hardwire zone cannot be Used as a fire zone. a. Connectsensors/contacts to the hardwired zone terminals 6 (+) and 7 (–). Refer to the Summary of Connections diagram. b. Connectclosed circuit devices in series in the high (+) side of the loop. The EOL resistor must be connected in series with the devices, following the last device. c. Connectopen circuit devices in parallel across the loop. The 2000 ohm EOLR must be connected across the loop at the last device.