Validation of the _1hn1_1hn3C-sodium-acetate breath test for the measurement of gastric emptying in dogs in comparison to _1hn9_1hn9_1hnmtechnetium radioscintigraphy [Elektronische Ressource] / eingereicht von Silke Schmitz
66 pages
English

Validation of the _1hn1_1hn3C-sodium-acetate breath test for the measurement of gastric emptying in dogs in comparison to _1hn9_1hn9_1hnmtechnetium radioscintigraphy [Elektronische Ressource] / eingereicht von Silke Schmitz

Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres
66 pages
English
Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres

Description

13VALIDATION OF THE C-SODIUM-ACETATE BREATHTEST FOR THE MEASUREMENT OF GASTRIC99MEMPTYING IN DOGS IN COMPARISON TO TECHNETIUM RADIOSCINTIGRAPHYSILKE SCHMITZINAUGURAL-DISSERTATIONzur Erlangung des Grades eines Dr. med. vet. beim Fachbereich Veterinärmedizinder Justus-Liebig-Universität Gießen édition scientifiqueVVB LAUFERSWEILER VERLAGVVB LAUFERSWEILER VERLAG ISBN 3-8359-5224-2ST AU FEN BER G R I N G 1 5D - 3 5 3 9 6 G I E S S E NTel: 0641-5599888 Fax: -5599890redaktion@doktorverlag.dew w w . d o k t o r v e r l a g . d e 9 7 8 3 8 3 5 9 5 2 2 4 9édition scientifiqueVVB VVB LAUFERSWEILER VERLAGSILKE SCHMITZ CANINE GASTRIC EMPTYINGDas Werk ist in allen seinen Teilen urheberrechtlich geschützt. Jede Verwertung ist ohne schriftliche Zustimmung des Autors oder des Verlages unzulässig. Das gilt insbesondere für Vervielfältigungen, Übersetzungen, Mikroverfilmungen und die Einspeicherung in und Verarbeitung durch elektronische Systeme.1. Auflage 2007All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the Author or the Publishers.

Informations

Publié par
Publié le 01 janvier 2007
Nombre de lectures 19
Langue English
Poids de l'ouvrage 2 Mo

Extrait

13VALIDATION OF THE C-SODIUM-ACETATE BREATH
TEST FOR THE MEASUREMENT OF GASTRIC
99MEMPTYING IN DOGS IN COMPARISON TO
TECHNETIUM RADIOSCINTIGRAPHY
SILKE SCHMITZ
INAUGURAL-DISSERTATION
zur Erlangung des Grades eines
Dr. med. vet.
beim Fachbereich Veterinärmedizin
der Justus-Liebig-Universität Gießen

édition scientifique
VVB LAUFERSWEILER VERLAG
VVB LAUFERSWEILER VERLAG ISBN 3-8359-5224-2
ST AU FEN BER G R I N G 1 5
D - 3 5 3 9 6 G I E S S E N
Tel: 0641-5599888 Fax: -5599890
redaktion@doktorverlag.de
w w w . d o k t o r v e r l a g . d e 9 7 8 3 8 3 5 9 5 2 2 4 9
édition scientifique
VVB VVB LAUFERSWEILER VERLAG
SILKE SCHMITZ CANINE GASTRIC EMPTYINGDas Werk ist in allen seinen Teilen urheberrechtlich geschützt.
Jede Verwertung ist ohne schriftliche Zustimmung des Autors
oder des Verlages unzulässig. Das gilt insbesondere für
Vervielfältigungen, Übersetzungen, Mikroverfilmungen
und die Einspeicherung in und Verarbeitung durch
elektronische Systeme.
1. Auflage 2007
All rights reserved. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without the prior
written permission of the Author or the Publishers.
st
1 Edition 2007
© 2007 by VVB LAUFERSWEILER VERLAG, Giessen
Printed in Germany
VVB LAUFERSWEILER VERLAG
édition scientifique
STAUFENBERGRING 15, D-35396 GIESSEN
Tel: 0641-5599888 Fax: 0641-5599890
email: redaktion@doktorverlag.de
www.doktorverlag.deAus dem Klinikum Veterinärmedizin
der Justus-Liebig-Universität
Klinik für Kleintiere (Innere Medizin)

Betreuer: Prof. Dr. R. Neiger



13Validation of the C-sodium-acetate breath test for
the measurement of gastric emptying in dogs in
99mcomparison to Technetium radioscintigraphy





INAUGURAL-DISSERTATION
zur Erlangung des Grades eines
Dr. med. vet.
beim Fachbereich Veterinärmedizin
der Justus-Liebig-Universität Gießen





eingereicht von



Silke Schmitz

Tierärztin aus Oberhausen




Gießen 2007
2Mit Genehmigung des Fachbereiches Veterinärmedizin
der Justus-Liebig-Universität Gießen



Dekan: Prof. Dr. Dr. habil. G. Baljer

Gutachter: Prof. Dr. R. Neiger
Prof. Dr. A. Wehrend



Tag der Disputation: 20. November 2007





















3Ich erkläre:

Ich habe die vorgelegte Dissertation selbständig und ohne unerlaubte
fremde Hilfe und nur mit den Hilfen angefertigt, die ich in der Dissertation
angegeben habe. Alle Textstellen, die wörtlich oder sinngemäß aus
veröffentlichten oder nicht veröffentlichten Schriften entnommen sind,
und alle Angaben, die auf mündlichen Auskünften beruhen, sind als
solche kenntlich gemacht. Bei den von mit durchgeführten und in der
Dissertation erwähnten Untersuchungen habe ich die Grundsätze guter
wissenschaftlicher Praxis, wie sie in der „Satzung der Justus-Liebig-
Universität Gießen zur Sicherung guter wissenschaftlicher Praxis“
niedergelegt sind, eingehalten.



Silke Schmitz
Gießen 2007
4Abbreviations
ADP Adenosinediphosphate
AMP Adenosinemonophosphate
APT Applied potential tomography
ATP Adenosinetriphosphate
BER Basal electrical rhythm
BIPS Barium impregnated poyethylene spheres
°C Degree celsius
12C Naturally occuring isotope of carbon
13C Non-radioactive isotope of carbon with 13 electrons
13 13C-OABT C-octanoic acid breath test
13 13C-SABT C-sodium acetate breath test
14C Radioactive isotope of carbon with 14 electrons
CCK Cholecystokinine
cm Centimetres
CNS Central nervous system
CO Carbon dioxide 2
CPM Counts per minute
CT Computed tomography
DPTA Diethyltriamine triamine pentacetic acid
DOB Delta over baseline
ECA Electrical contractile activity
EIM Electrical impedance measurements
ENS Enteric neuronal system
ERA Electrical response activity
g Gram(s)
GIP Gastric inhibitory polypeptide
GEC Gastric emptying coefficient
GLP-1 Glucagone-like peptide-1
GRP Gastrine releasing peptide
G Gastric half emptying time t1/2
H O Chemical formula of water 2
111In Radioactive 111-Indium
IE Impedance epigastrography
IRMS Isotope ratio mass spectrometry
kg Kilogram(s)
LAG Lag phase of gastric emptying
mBq Megabequerell
mg Milligram(s)
ml Milliliter(s)
MMC Migrating motor complex
MRI Magnetic resonance imaging
NANC Non-adrenergic-non-cholinergic
NDIRS Non-dispersive isotope-selective infrared spectroscopy
NO Nitric oxid
PMP Electrical pacemaker potentials
ppm Parts per million
RER Resting energy requirements
ROI Region of interest
99mTc Radioactive 99m-technetium
VIP Vasoactive intestinal peptide
Contents:
I. Introduction............................................................................................................................8
II. Literature review..................................................................................................................9
1. Historical background .....................................................................................................9
2. Physiology of gastric emptying ......................................................................................9
2.1. Morphological and functional structure of the canine stomach ........................9
2.2. The stomach as a store.........................................................................................10
2.3. The gastric pump ...................................................................................................11
2.4. Physiology of gastric emptying and trituration...................................................12
2.5. Neuronal regulation of gastric motility ................................................................15
2.6. Influences on gastric motility................................................................................15
2.7. Interdigestive motility patterns and the migrating motor complex ..................16
2.8. Pathology of gastric emptying ..............................................................................17
3. Methods for the assessment of gastric emptying in dogs.......................................19
3.1. Diagnostic imaging.................................................................................................20
3.2. Other methods to assess the rate of gastric emptying ....................................22
4. Aim of the study.............................................................................................................25
III. Hypotheses .......................................................................................................................26
IV. Material and methods......................................................................................................27
1. General considerations .............................................................................................27
1.1. Subjects...................................................................................................................27
1.2. Test meal composition ..........................................................................................27
1.3. Study design ...........................................................................................................28
132. C-sodium acetate breath test ...................................................................................28
2.1. Test procedure .......................................................................................................28
2. 2. Automatic data analysis and calculation of gastric emptying values:...........29
2.3. Software for breath test analysis .........................................................................33
99m3. Technetium colloid radioscintigraphy....................................................................34
3.1. Evaluation of the radioscintigraphic image sequences ....................................35
3.2. Mathematical curve fitting of scintigraphic images ...........................................36
4. Statistical evaluation of results....................................................................................38
V. Results ................................................................................................................................39
1. Baseline results .............................................................................................................39
132. C-sodium acetate breath test ..........................................................................

  • Univers Univers
  • Ebooks Ebooks
  • Livres audio Livres audio
  • Presse Presse
  • Podcasts Podcasts
  • BD BD
  • Documents Documents