Notice Sécurité Ademco  VISTA-15P
1 page
Français

Notice Sécurité Ademco VISTA-15P

-

Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres
1 page
Français
Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres

Description

Notice utilisateur, mode d'emploi du modèle 'VISTA-15P' de marque 'Ademco'

Sujets

Informations

Publié par
Nombre de lectures 138
Langue Français

Extrait

LYNX Touch Installation and Setup GuideSystem Operation Event Log The LYNX Touch Series event log is capable of recording and displaying up to 128 system events. The type of events that can be recorded is selectable and is programmed in the System Type programming field. The event log can be reviewed by entering the Installer Programming or Master User Programming mode. Refer to the LYNX Touch Series User Manual for additional information. Note: Inthe unlikely condition that the backup battery becomes fully discharged when AC power is lost, any system activity performed after the low battery notification will not be saved in the event log. Additionally, the panel will revert to the status condition as before the low battery notification.® Contact ID& SIA Event Log CodesCID SIA CodeDefinitionCode Definition 110 Alarm,FireAC Trouble/AC Restoral AT/AR 121 Alarm,Duress BA/BRBurglary Alarm/Burglary Restoral 122 Alarm,Silent BB/BUBurglary Bypass/Burglary Unbypass 123 Alarm,AudibleClosing/Closing Delinquent CA/CD Automatic 131 Alarm,Perimeter CIFail to Close 132 Alarm,InteriorClosing Report CL 134 Alarm,Entry/ExitRemote Closing CQ 135 Alarm,Day/Night CRRecent Closing 137 Alarm,TamperDoor Forced/Door Restoral DF/DR 145 ExpansionModule TamperEA ExitAlarm 146 SilentBurglary EM/EN ExpansionDevice Missing/Expansion Missing Restore 150 24HourNonBurglary ES/EJExpansion Device Tamper/Expansion Tamper Restore 162 CarbonMonoxide Detected ETExpansion Trouble 301 Trouble,AC Loss FAFire Alarm 302 Trouble,Low System Battery FT/FJFire Trouble/Fire Trouble Restore 305 Trouble,System ResetHA/HR HoldupAlarm/Holdup Restoral 341 Trouble,Case TamperJL LogThreshold 344 Trouble,RF Receiver Jam Detect LB/LXLocal Progr./Local Progr. End (Logged in Event Log ) 351 Trouble,Telco 1 FaultPhone Line Trouble/Phone Line Restoral LT/LR 353 Trouble,Long Range Radio Transmitter Fault MA/MR MedicalAlarm/ Medical Restoral 354 Trouble,Failure to Communicate Event OAAutomatic Opening 373 Trouble,Fire TroubleCancel Report OC 374 Trouble,Exit Error AlarmOP OpeningReport 380 Trouble,SensorRemote Opening OQ 381 Trouble,Loss of Supervision RFPanic Alarm PA 383 Trouble,Sensor Tamper RPAutomatic Test 384 RFLow Battery RSRemote Program Success 401 Open/Closeby User RXManual Test 403 Open/CloseAutomatic TA/THTamper Alarm/Tamper Alarm Restore 406 CancelTamper Trouble Restore TJ 407 RemoteArm/Disarm TS/TETest Start/Test End 408 QuickArmTamper Trouble TT 409 Open/CloseKeyswitch UAUntyped Zone Alarm 412 SuccessfulDownload UB/UUUntyped Zone Bypass/Untyped Zone Unbypass 441 ArmedStay WA/WRWater Alarm/Water Restoral 455 AutoArmFailed XG/XHRF Interference/RF Interference Restore 459 RecentClose XT/XRTransmitter Battery Trouble/Transmitter Battery Restoral 570 Zone/SensorBypassCommunications Fail/Communications Restoral YC/YK 601 ManualTrigger Test Report YMSystem Battery Missing 602 PeriodicTest Report YT/YRSystem Battery Trouble/System Battery Restoral 606 Listeninto follow607 WalkTest623 EventLog 80% Full627 ProgramMode Entry (Logged in Event Log Only)628 ProgramMode Exit (Logged in Event Log Only)654 SystemInactivity759 ResidentMonitor Zone Response 760 ResidentResponse Zone Response 761 GeneralMonitor Zone Response 762 GeneralResponse Zone Response Note:LRR/IP Communications Module Low Battery and Low Battery restore reports are sent real time. LRR/IP Communications Module trouble restore report is sent after two OFF Sequences (only if physically restored).
 54 
  • Univers Univers
  • Ebooks Ebooks
  • Livres audio Livres audio
  • Presse Presse
  • Podcasts Podcasts
  • BD BD
  • Documents Documents