NEBULA - A Future Internet That Supports Trustworthy Cloud Computing
12 pages
English

NEBULA - A Future Internet That Supports Trustworthy Cloud Computing

Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres
12 pages
English
Le téléchargement nécessite un accès à la bibliothèque YouScribe
Tout savoir sur nos offres

Description

NEBULA - A Future Internet That Supports Trustworthy Cloud Computing Tom Anderson, Ken Birman, Robert Broberg, Matthew Caesar, Douglas Comer, Chase Cotton, Michael Freedman, Andreas Haeberlen, Zack Ives, Arvind Krishnamurthy, William Lehr, Boon Thau Loo, David Mazières, Antonio Nicolosi, Jonathan Smith, Ion Stoica, Robbert van Renesse, Michael Walfish, Hakim Weatherspoon and Christopher Yoo Abstract NEBULA is a future Internet architecture that is intrinsically more secure and addresses threats to the emerging computer utility capabilities called cloud computing while meeting the challenges of flexibility, extensibility and economic viability.
  • control-plane
  • control plane
  • nebula data plane
  • model of computing
  • router
  • cloud computing
  • path
  • policy
  • security
  • packet
  • data

Sujets

Informations

Publié par
Nombre de lectures 57
Langue English
Poids de l'ouvrage 1 Mo

Extrait

PRODUCT OVERVIEW
ECS Retroft Power Solution
Cost-Effective Energy Effciency Upgrade Benefts
Reliability
• Preserves distribution and – Extends the lifecycle of deployed
ECS power plantscabling investments
– Proven feld performance
• Modern Galaxy Pulsar Plus controller
– Controller continuity
– Adaptive Rectifer Management
Intelligence(effciency management)
– Industry leading controller features
– Thermal compensation and
– Ethernet interface for remote accessbattery management features
– Centralized network management
• -48V up to 600A (16.2 KW) or
Investment Protection+24V up to 1200A (16.3 KW)
– Energy effciency improvement
• Effciency approaching 97%
– Avoids complete replacement costs
On Time Delivery
– Comprehensive turn-key retroft
service including plant assessment
– Fast track deploymentOverview
– 24/7 supportLineage Power offered the Lineage 2000 All existing system rectifer shelf slots
ECS telecom power systems throughout require a retroft carrier or permanent
the 1980s and 1990s. The Lineage ECS slot fller since all rectifers deployed in
Retroft Power Solution enables these an ECS system must be upgraded. The
legacy power systems to be upgraded desired capacity of standard Infnity
to modern rectifers and controller rectifers are then inserted into the retroft
technology, while leaving the distribution, carrier modules. No change is needed
Total Effciency
shelves and frame in place. to the output distribution, batteries, or
The Lineage Power Total Effciency™ LVD contactor of the ECS plants with this
The ECS Retroft Power Solution upgrades (TE) architecture reduces energy loss retroft.
and lowers cooling costs by 50-70%. the legacy 364 series rectifers with
TE products will prioritize sustainable Lineage Power Infnity™ series of rectifers The ECS retroft power solution provides
energy sources like solar, wind, water to improve energy effciency and deliver a turn-key, cost-effective maintenance
and fuel cells over traditional utility grid centralized management visibility and upgrade for the installed base of ECS
or diesel generator sources – and they
control. The Infnity rectifers are managed telecom power systems. For most
will intelligently respond to smart grid
by the modern Galaxy Pulsar Plus™ applications, the retroft procedure may information to reduce consumption
controller. be accomplished in less than 4 hours. during peak demand periods. Active
Rectifer Management (ARM) and
Battery Charging Optimization (BCO)
features increase effciency on current
and legacy power infrastructures. The
Total Effciency architecture addresses
issues end-to-end based on our proven
experience and expertise in batteries,
power distribution, DC energy systems,
AC-DC power supplies, and DC-DC
board mounted power to deliver a
solution that is more safe, reliable and
energy effcient than alternatives from
our competitors.
08/11 ECS Retroft Power Solution © 2011 Lineage Power. All rights reserved.TECHNICAL SPECIFICATIONS – POWER MODULES
Infnity Rectifers
• Compact - 1RU form factor providing high power density (24 W/in3)
• Plug and Play – installation of the rectifer in a shelf connected to a compatible system
controller initializes all set up parameters automatically. No adjustments are needed.
• Extended service life – parallel operation with automatic load sharing ensures that
parallel units are not unduly stressed even when a unit fails or is removed.
• Monitoring / control – the built in microprocessor controls and monitors all critical
rectifer functions and communicates with the system controller using the built in
Galaxy Protocol serial interface.
• Fail safe performance – hot insertion capabilities allow for rectifer replacement without
system shutdown; soft start and inrush current protection prevent nuisance tripping of
upstream breakers.
Applications
• Telecommunications networks • Routers/switches • Data networks
• Digital subscriber line (DSL) • Fiber in the loop • PBX
• Indoor/outdoor wireless • Transmission
Key Features
• Extended temperature range • 1U height, hi power density • Hot pluggable
• Redundant fan cooling • 220/110 V AC input • RoHS compliant
• Front panel LED indicators • Digital load sharing
Specifcations
Input NE100AC24 NE050AC48
Voltage Range
- High-Line 175-275Vac 175-275Vac
- Low-Line 85-140Vac -
Input Current 14.9A @208Vac 14.5A @208Vac
12.9A @240Vac 12.6A @240Vac
Input Frequency 45 – 66Hz 45 – 66Hz
Power Factor 0.98 at >50% load 0.98 at >50% load
Effciency 92% 93%
Total Harmonic Distortion 5% at full load 5% at full load
Output
Voltage Adjust Range 21-29Vdc 42-58Vdc
Voltage Nominal 27.25V 54.5V
Regulation(with controller) ±0.5% ±0.5%
Ripple 100mV rms 100mV rms
Psophometric Noise 2 mV 2 mV
Output Current
- High-Line 100A @27.25V 50A @54.5V
- Low-Line 44A @27.25V -
Heat Dissipation @ max out 237W / 808 BTU/hr 205W / 699 BTU/hr
08/11 ECS Retroft Power Solution © 2011 Lineage Power. All rights reserved. Page 2TECHNICAL SPECIFICATIONS – POWER MODULES
Environmental
Operating Temperature -40°C to +75°C (-40 to 167 °F)
Storage Te -40°C to +85°C (-40 to 185 °F)
Power De-Rating 2% per ºC from +65ºC to +75ºC
Relative Humidity 95% max, non-condensing
Altitude 2,000M max
Mechanical
Length (in. /mm) 13.85 / 351.8
Width (in. /mm) 5.25 / 132.8
Height (in. /mm) 1.70 / 43.2
Weight (lb / Kg) 5.2 / 2.4
Safety and Standards Compliance
NEBs Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 and GR1089-CORE, Issue 5
Safety CE mark to Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/E (Rectifers Only)
UL 609501-1, 2nd Ed. Recognized
CSA C22.2 No. 60950-1-03 Certifed
RoHS Compliant to RoHS EU Directive 2002/95/EC; RoHS 5/6
EMC European Directive 2004/108/EC; EN55022, Class A; EN55024; FCC, Class A; GR1089-CORE, Issue 5
Outline Drawing
08/11 ECS Retroft Power Solution © 2011 Lineage Power. All rights reserved. Page 3TECHNICAL SPECIFICATIONS - CONTROLLER
Pulsar Plus Controller
The Pulsar Plus family of controllers to the World Wide Web (internet) or your
provides system monitoring and control enterprise network (intranet). An optional
features for Infnity, CP, and other power modem is also available.
systems. These controllers monitor and
This controller utilizes standard network control system components including
management protocols allowing for rectifers, converters, and distribution
advanced network supervision. Lineage modules via a multi-drop RS485 digital
Power Galaxy Manager™ software communications bus. System status, 

is the centralized visibility and control parameters, settings, and alarm thresholds
component of a comprehensive can be viewed and confgured from the
power management system designed controller’s front panel display. Assignment
to meet engineering, operations and and confguration of alarm inputs and
maintenance needs. The Galaxy Manager output relays can be performed from a
client-server architecture enables remote laptop computer connected to a local
access to system controllers across the RS-232 or Ethernet port, or by remote
power network.access is through a network connection
Applications
• Telecommunications networks • Routers/switches • Data networks
• Digital subscriber line (DSL) • Fiber in the loop • PBX
• Indoor/outdoor wireless • Transmission
Key Features
Remote Access and Features Standard System Features Standard Battery Management Features
• Integrated 10/100Base-T Ethernet • Monitor and control of more than 60 • Float/boost mode control
Network connected devices - Manual boost
- TCP/IP - Robust RS485 system bus - Manual timed boost locally, T1.317,
- SNMP V2c for management and remotely initiated • Standard and user defned alarms
- SMTP for email - Auto boost terminated by time - Alarm test
- Telnet for command line interface or current- Assignable alarm severity: Critical,
- DHCP for plug-n-play Major, Minor, Warning, and record-only • Battery discharge testing
- FTP for rapid backup and upgrades - 10 alarm relays (7 user assigned) - Manual (local/remote)
- HTTP for standard web pages and - Periodic • Rectifer management features browsers - Plant Battery Test (PBT) input driven - Automatic rectifer restart - Compatible with Galaxy Manager - Confgurable threshold or - Active Rectifer Management and other management packages 20% algorithm ARM (energy effciency) - Shielded RJ-45 interface referenced - Graphical discharge data - Remote rectifer (on/off) to chassis ground - Rectifers on-line during test - Reserve Operation
• Password protected security levels: User, - Automatic rectifer sequence control • Slope thermal compensation
Super-User, Administrator for all access - N + X redundancy check - High temperature
• Ground-referenced RS232 system port - Low temperature • Multiple Low Voltage Load and Low
- Step temperature • ANSI T1.317 command-line interface Voltage Battery Disconnect thresholds
- STC Enable/Disable, low temperature
• Modem access support • Confguration, statistics, and history Enable/Disable
- Remote via external modem - All stored in non-volatile memory

  • Univers Univers
  • Ebooks Ebooks
  • Livres audio Livres audio
  • Presse Presse
  • Podcasts Podcasts
  • BD BD
  • Documents Documents