pe fHome:Wood/Brick Veneer OWood FrameBrick Veneerne Veneerasonry TySto M Single StoryStory and a halfTwo StorTri/BiLevel MultipleStories Number of Stories: Roof MaterialAsphalt FiberglassSlate AsbestosCementWood ShakeRolled Mineral Year Built1870# of Bedrooms4# of Occupants3Sq Ft2,400Ave Ceiling8.5 General Info Light MediuLight Dark m Dark Exterior Wall ColorRoof ColorMedium
Comments:Extend the run off drains to carry rain water well away from the foundation.Repair the roof as needed.
Page 1
6/10/2008
Sample audit checklist
Cooling System:
A/C H/P Fins:
Energy Performance Partners, LLC
HVAC & Plumbing System
Air Conditioner Manufacturer Heat PumpModel Number Manufacturer's Rated Amperage
Clean and Free of Debris Fins are Slightly Damaged
Trane TTX024C100A1
Recommend Cleaning Coils Bushes Need Trimmed
Approximate Tons Approximate Age
Serviceable
2 8
Needs work
x
Ext. Coolant Lines:Insulated InteriorInsulation Kinked/Damaged Elec. Disconnect:Exterior30 Amps:InteriorAmps: 30 A/C System Test:Temp in:Temp Out:Variance:not tested ManufacturerTraneRated BTU/Hr.60,000Approximate Age8yrs. Heating System:Type:Gas Oil ElectricBoiler Model NumberTDD060R936B1 90% Efficiency:High 9296%Low Under 70%78% 80% Belt DrivenDirect DriveGravity ReasonablyClean Dirty Hot Air System:x Flue Piping:Induction Fan?x Single DoublePVC YesNo Up DownHorizontal MetalDucts FlexibleDucts Distribution System:x % Inside:10.0%% Outside:90.0%% Insulated20.0%% Uninsulated80.0% Duct System: Overall leakage @ 25Pa.2,900CFM Thermostat:ProgrammableZones ElectronicSingle Multiple Multiplex Boiler Circulation:Gravity System # of Zones # of Pumps High Temp/Pressure ValveLimit Switch Backflow Preventer Boiler Controls: Main Fuel Shutoff:Electric (N/A)Location? WestTest yard LeakX Wall or Recessed Resistance Convection Baseboard Electric Units Non Forced AirRadiant Ceiling/Floor Panel IR Test o o Thermostat: Heat60A/C80On Off FanAuto On ManufacturerBradford WhiteRated BTU/Hr.40,000Approx. Age4yrs. Size40gals. Water Heater: Type:BoilerGas ElectricModel#MI40 Off Status:Water GasElectric HT/P Valve:x Valve is Compatible with SystemValve is Not Compatible with System HT/P pipe OKNo pipe is installed HT/P pipe not OK HT/P Pipe:x Plastic (PVC) Single Walle d DoubleWalled N/A Flue Pipe:x Gas Piping:Dirt Leg?x Valve OnValve OffN/A YesNo
Comments:Water heater flue pipe incline should be increased.
Page 2
6/10/2008
Sample audit checklist
Plumbing System:
Energy Performance Partners, LLC
Water Source:
Plumbing Municipal PrivateWell Drainage:
Municipal Sewer
Septic System
Main Supply Pipe:1 inchOther Other3/4 inch Copper Crawl Other Basement UtilityRoom GarageSpace Main Shut Off:x Copper Plastic(PVC) PolyPEX GalvanizedLead Interior Pipes:x Waste Pipes:x Cast IronGalvanized LeadCopper Plastic Electrical Panel Main Service Voltage120 v/240 v120 vDrip Loop?Yes NoUnderground Cable Electrical Service: Yes No Overhead ClearanceFeetExtension Mast?Exterior wire amps200 Serviceable Needswork Accessibility: Maintain 36" free accessAverage Restricted Main Distribution Main Panel Rated: 100 Amps150 Amps200 Amps60 Amps Panel: Location:Utility RoomBasement GarageExterior Other Copper AluminumTin Coated Coppe Main Service Wire: Main Service Wire Size2/0Compatibility Amperage200 Circuit Wires:Compatible OverfusedCompatible Not Double Taps Conduit Knob& TubeGreenfield RomexBX Cable Type of House Wire: Basement and Crawlspace Foundation Type:Partial CrawlMultiple CrawlsFull BasementSlabFull CrawlWalk Out or DrainSump PumpNone Flo YesNo Drainage:Tested? Unfinished Finished PartiallyFinished PaneledDrywall Wall Finish:
Interior Room Dishwasher:NoneManufacturer:MaytagApprox Age:15x OperableAge +:On10 PowerOff Refrigerator: Watt hour meter readingkw used Ceiling WallNone Exhaust Fan:HoodCFM Actual250x Gas Range/Oven:Builtin FreeStanding ElectricOnly gas ovens will be tested for CO. Gas Range CO:CO PPM from CAZ Testing Master FirstFloor SecondFloor Other Bathroom #1: Fan #1 Actual CFM150Fan #2 Actual CFMx Master FirstFloor SecondFloor Other Bathroom #2: Fan #1 Actual CFM80Fan #2 Actual CFMx Master FirstFloor SecondFloor Other Bathroom #3: Fan #1 Actual CFMFan #2 Actual CFM Location: Other Exhaust Fan: Fan #1 Actual CFMFan #2 Actual CFM Smoke Detectors:None CO Meters:None Fireplace #1Type:Wood burning insertLocation:Living roomx Fireplace #2Type: Location: Fireplace #3Type: Location: Attic Closet HatchPulldown S Access:Stairway Othertairs FixedGarage HatchHallway Hatch Ease of Access:DifficultDifficult Very Routine Pull Down Stairs:Width22"Length6'Other: WidthLength Access Hatches Ceiling Scuttle:Width LengthOther: WidthLength Thickness6.0Condition:Poor/mar ina Attic Floor Insulation: Fiberglass CelluloseRock WoolRoll/Batt Loose Fill Other Attic AreaThickness12.0Condition:Ok Floor Insulation:Fiberglass CelluloseRock WoolRoll/Batt LooseFill Other Attic AreaThickness0.0Condition: Floor Insulation:Fiberglass CelluloseRock WoolRoll/Batt LooseFill Gable EndsRoof RidgeRoof VentsNone Ventilation: Soffit PowerFan Whole House Fan Roof Turbines Width20Length25Width4Length25Width Length Attic square Feet: Width15Length20Width LengthWidth Length Comments: