Description

Energy Performance Partners, LLCHouse SystemsType Of Home: Wood/Brick Veneer Wood Frame Brick Veneer Stone Veneer MasonrySingle Story Story and a half Two Story Tri/Bi-Level Multiple Stories -Number of Stories:Roof Material Asphalt Fiberglass Wood Shake Rolled Mineral Slate Asbestos Cement1870 4 3 2,400 8.5Year Built # of Bedrooms # of Occupants Sq Ft Ave CeilingGeneral InfoMedium DarkLight Light DarkExterior Wall Color Roof Color MediumCombinationGable MansardRoof Style Gambrel Hip Shed Flat OtherObserved ConditionsServiceable Needs workRoof Covering: xLast thirdFirst third of useful life Second thirdSoffitVentilation Systems: Turbine xFanRidge Gable Roof NonePlumbing Vents: CopperCopper xCast Iron Plastic (PVC) OtherOtherChimney #1 North #2 East #3 #4Chimney(s):xMetalBrick Block Siding Wrapped Multiple FluesGutter Type: Copper xAluminum GalvanizedPlastic NoneDownspouts: CopperCopper xAluminum PlasticPlastic GalvanizedGalvanizedRun Offs: xGalvanized NoneAluminum Plastic Copper TilesGrading: xTowards Foundation MixAdequate Neutral Adjoining TowardsVinylAluminum/Steel Wood Stucco Brick/Stone VeneerSiding Type:Wood Shingle xAsbestos Shingle Wood Composite EIFSStoneStoneFoundation: Block Poured Brick Slab xWoodWood Aluminum VinylSoffits-Fascia: Other xMetal Fiberglass SlidingEntry Doors: Wood xWindows: Wood Steel Vinyl Aluminum Single Glazed xInsulatedAluminum StormsAluminum Storms Wood StormsWood Storms NoneNoneStorms: Vinyl StormsVinyl ...

Informations

Publié par
Nombre de lectures 24
Langue English

Extrait

Energy Performance Partners, LLC
House Systems
pe fHome:Wood/Brick Veneer OWood FrameBrick Veneerne Veneerasonry TySto M Single StoryStory and a halfTwo StorTri/BiLevel MultipleStories  Number of Stories: Roof MaterialAsphalt FiberglassSlate AsbestosCementWood ShakeRolled Mineral Year Built1870# of Bedrooms4# of Occupants3Sq Ft2,400Ave Ceiling8.5 General Info Light MediuLight Dark m Dark Exterior Wall ColorRoof ColorMedium
Gable MansardCombination Roof StyleOtherShed FlatGambrel Hip Observed Conditions Serviceable Roof Covering:Last thirdFirst third of useful lifeSecond third Ventilation Systems:Ridge Gable RoofFan None Soffit Turbin Plumbing Vents:Cast IronPlastic (PVC)Other Copper Chimney #1North#2East#3 #4 Chimney(s): Brick Block Metal SidingWrapped MultipleFlues Gutter Type:Aluminum PlasticGalvanized None Copper Downspouts:GalvanizedAluminum Plastic Copper Run Offs:NoneGalvanized Aluminum PlasticCopper Tiles Grading:Neutral AdjoiningTowardsAdequate TowardsFoundation Mix Vinyl Aluminum/Steel WoodStucco Brick/StoneVeneer Siding Type: Wood Shingle Asbestos ShingleWood CompositeEIFS one Foundation:Brick WoodSt SlabBlock Poured Wood SoffitsFascia:OtherAluminum Vinyl Entry Doors:Fiberglass SlidingWood Metal Windows:Vinyl AluminumWood SteelI ulatSingle Glazed ns ed Aluminum StormsWood StormsNone Vinyl Storms Storms: Weather Stripping:Metal Feltor FiberRubber or VinylNone Caulking:Siding EndsWindows DoorsOther Garage:area aboveAttached LivingDetached
Needs work
Comments:Extend the run off drains to carry rain water well away from the foundation.Repair the roof as needed.
Page 1
6/10/2008
Sample audit checklist
Cooling System:
A/C  H/P Fins:
Energy Performance Partners, LLC
HVAC & Plumbing System
Air Conditioner ManufacturerHeat PumpModel Number  Manufacturer's Rated Amperage
Clean and Free of Debris Fins are Slightly Damaged
Trane TTX024C100A1
Recommend Cleaning Coils Bushes Need Trimmed
Approximate Tons Approximate Age
Serviceable
2 8
Needs work
x
Ext. Coolant Lines:Insulated InteriorInsulation Kinked/Damaged Elec. Disconnect:Exterior30 Amps:InteriorAmps: 30 A/C System Test:Temp in:Temp Out:Variance:not tested ManufacturerTraneRated BTU/Hr.60,000Approximate Age8yrs. Heating System:Type:Gas Oil ElectricBoiler Model NumberTDD060R936B1 90% Efficiency:High 9296%Low  Under 70%78% 80% Belt DrivenDirect DriveGravity ReasonablyClean Dirty Hot Air System:x Flue Piping:Induction Fan?x Single DoublePVC YesNo Up DownHorizontal MetalDucts FlexibleDucts Distribution System:x % Inside:10.0%% Outside:90.0%% Insulated20.0%% Uninsulated80.0% Duct System: Overall leakage @ 25Pa.2,900CFM Thermostat:ProgrammableZones ElectronicSingle Multiple Multiplex Boiler Circulation:Gravity System # of Zones # of Pumps  High Temp/Pressure ValveLimit Switch Backflow Preventer Boiler Controls: Main Fuel Shutoff:Electric (N/A)Location? WestTest yard LeakX Wall or Recessed Resistance Convection Baseboard Electric Units  Non Forced AirRadiant Ceiling/Floor Panel IR Test  o o Thermostat: Heat60A/C80On Off FanAuto On ManufacturerBradford WhiteRated BTU/Hr.40,000Approx. Age4yrs. Size40gals. Water Heater: Type:BoilerGas ElectricModel#MI40 Off Status:Water GasElectric HT/P Valve:x Valve is Compatible with SystemValve is Not Compatible with System HT/P pipe OKNo pipe is installed HT/P pipe not OK HT/P Pipe:x Plastic (PVC) Single Walle d DoubleWalled N/A Flue Pipe:x Gas Piping:Dirt Leg?x Valve OnValve OffN/A YesNo
Comments:Water heater flue pipe incline should be increased.
Page 2
6/10/2008
Sample audit checklist
Plumbing System:
Energy Performance Partners, LLC
Water Source:
Plumbing Municipal PrivateWell  Drainage:
Municipal Sewer
Septic System
Main Supply Pipe:1 inchOther Other3/4 inch Copper Crawl Other Basement UtilityRoom GarageSpace Main Shut Off:x Copper Plastic(PVC) PolyPEX GalvanizedLead Interior Pipes:x Waste Pipes:x Cast IronGalvanized LeadCopper Plastic Electrical Panel Main Service Voltage120 v/240 v120 vDrip Loop?Yes NoUnderground Cable Electrical Service: Yes No Overhead ClearanceFeetExtension Mast?Exterior wire amps200 Serviceable Needswork Accessibility: Maintain 36" free accessAverage Restricted Main Distribution Main Panel Rated: 100 Amps150 Amps200 Amps60 Amps Panel: Location:Utility RoomBasement GarageExterior Other Copper AluminumTin Coated Coppe Main Service Wire: Main Service Wire Size2/0Compatibility Amperage200 Circuit Wires:Compatible OverfusedCompatible Not Double Taps Conduit Knob& TubeGreenfield RomexBX Cable Type of House Wire: Basement and Crawlspace Foundation Type:Partial CrawlMultiple CrawlsFull BasementSlabFull CrawlWalk Out or DrainSump PumpNone Flo YesNo Drainage:Tested? Unfinished Finished PartiallyFinished PaneledDrywall Wall Finish:
Crawl Space:
Foundation Walls:
Floor: Drainage: Insulation: Ductwork: Ventilation: Comments:
Page 3
Full Partialw/Basement MultipleCrawlspaces Access Access RestrictedInner Hatch Exterior ViaBasement Yes No Crawlspace entered?yesTight Space?Dry Cement BlockPoured ConcreteStone Brick Piers & ColumnsCovered by insulation Spot Check Other Cement DirtStone VaporBarrier NoVapor Barrier
Floor DrainSump PumpFrench DrainNone Between Joiststwork None Walls SillDuc Insulated?No Supply Supplyand ReturnReturn None Wall VentsPower FanVia Basement
6/10/2008
x
Access Typical Damp Wet
x
x x x
Sample audit checklist
Energy Performance Partners, LLC
Interior Room Dishwasher:NoneManufacturer:MaytagApprox Age:15x OperableAge +:On10 PowerOff Refrigerator: Watt hour meter readingkw used Ceiling WallNone Exhaust Fan:HoodCFM Actual250x Gas Range/Oven:Builtin FreeStanding ElectricOnly gas ovens will be tested for CO. Gas Range CO:CO PPM from CAZ Testing Master FirstFloor SecondFloor Other Bathroom #1: Fan #1 Actual CFM150Fan #2 Actual CFMx Master FirstFloor SecondFloor Other Bathroom #2: Fan #1 Actual CFM80Fan #2 Actual CFMx Master FirstFloor SecondFloor Other Bathroom #3: Fan #1 Actual CFMFan #2 Actual CFM Location: Other Exhaust Fan: Fan #1 Actual CFMFan #2 Actual CFM Smoke Detectors:None CO Meters:None Fireplace #1Type:Wood burning insertLocation:Living roomx Fireplace #2Type: Location: Fireplace #3Type: Location: Attic Closet HatchPulldown S Access:Stairway Othertairs FixedGarage HatchHallway Hatch Ease of Access:DifficultDifficult Very Routine Pull Down Stairs:Width22"Length6'Other: WidthLength Access Hatches Ceiling Scuttle:Width LengthOther: WidthLength Thickness6.0Condition:Poor/mar ina Attic Floor Insulation: Fiberglass CelluloseRock WoolRoll/Batt Loose Fill Other Attic AreaThickness12.0Condition:Ok Floor Insulation:Fiberglass CelluloseRock WoolRoll/Batt LooseFill Other Attic AreaThickness0.0Condition: Floor Insulation:Fiberglass CelluloseRock WoolRoll/Batt LooseFill Gable EndsRoof RidgeRoof VentsNone Ventilation: Soffit PowerFan Whole House Fan Roof Turbines Width20Length25Width4Length25Width Length Attic square Feet: Width15Length20Width LengthWidth Length Comments: