Emphysema distribution and annual changes in pulmonary function in male patients with chronic obstructive pulmonary disease
8 pages
English

Découvre YouScribe en t'inscrivant gratuitement

Je m'inscris

Emphysema distribution and annual changes in pulmonary function in male patients with chronic obstructive pulmonary disease

Découvre YouScribe en t'inscrivant gratuitement

Je m'inscris
Obtenez un accès à la bibliothèque pour le consulter en ligne
En savoir plus
8 pages
English
Obtenez un accès à la bibliothèque pour le consulter en ligne
En savoir plus

Description

The progression of chronic obstructive pulmonary disease (COPD) considerably varies among patients. Those with emphysema identified by quantitative computed tomography (CT) are associated with the rapid progression assessed by forced expiratory volume in one second (FEV 1 ). However, whether the rate of the decline in lung function is independently affected by the regional distribution or the severity of emphysema in the whole lung is unclear. Methods We followed up 131 male patients with COPD for a median of 3.7 years. We measured wall area percent (WA%) in right apical segmental bronchus, total lung volume, percent low attenuation volume (LAV%), and the standard deviation (SD) of LAV% values from CT images of 10 isovolumetric partitions (SD-LAV) as an index of cranial-caudal emphysema heterogeneity. Annual changes in FEV 1 were then determined using a random coefficient model and relative contribution of baseline clinical parameters, pulmonary function, and CT indexes including LAV%, SD-LAV, and WA% to annual changes in FEV 1 were examined. Results The mean (SD) annual change in FEV 1 was −44.4 (10.8) mL. Multivariate random coefficient model showed that higher baseline FEV 1 , higher LAV%, current smoking, and lower SD-LAV independently contributed to an excessive decline in FEV 1 , whereas ratio of residual volume to total lung capacity, ratio of diffusing capacity to alveolar ventilation, and WA% did not, after adjusting for age, height, weight, and ratio of CT-measured total lung volume to physiologically-measured total lung capacity. Conclusions A more homogeneous distribution of emphysema contributed to an accelerated decline in FEV 1 independently of baseline pulmonary function, whole-lung emphysema severity, and smoking status. In addition to whole-lung analysis of emphysema, CT assessment of the cranial-caudal distribution of emphysema might be useful for predicting rapid, progressive disease and for developing a targeted strategy with which to prevent disease progression.

Sujets

Informations

Publié par
Publié le 01 janvier 2012
Nombre de lectures 14
Langue English

Extrait

Tanabeet al. Respiratory Research2012,13:31 http://respiratoryresearch.com/content/13/1/31
R E S E A R C HOpen Access Emphysema distribution and annual changes in pulmonary function in male patients with chronic obstructive pulmonary disease 1 1* 2 11 1 Naoya Tanabe , Shigeo Muro, Shiro Tanaka , Susumu Sato , Tsuyoshi Oguma , Hirofumi Kiyokawa , 1 1 13 1 1 Tamaki Takahashi , Daisuke Kinose , Yuma Hoshino , Takeshi Kubo , Emiko Ogawa , Toyohiro Hirai 1 and Michiaki Mishima
Abstract Background:The progression of chronic obstructive pulmonary disease (COPD) considerably varies among patients. Those with emphysema identified by quantitative computed tomography (CT) are associated with the rapid progression assessed by forced expiratory volume in one second (FEV1). However, whether the rate of the decline in lung function is independently affected by the regional distribution or the severity of emphysema in the whole lung is unclear. Methods:We followed up 131 male patients with COPD for a median of 3.7 years. We measured wall area percent (WA%) in right apical segmental bronchus, total lung volume, percent low attenuation volume (LAV%), and the standard deviation (SD) of LAV% values from CT images of 10 isovolumetric partitions (SDLAV) as an index of cranialcaudal emphysema heterogeneity. Annual changes in FEV1were then determined using a random coefficient model and relative contribution of baseline clinical parameters, pulmonary function, and CT indexes including LAV%, SDLAV, and WA% to annual changes in FEV1were examined. Results:The mean (SD) annual change in FEV1was44.4 (10.8) mL. Multivariate random coefficient model showed that higher baseline FEV1, higher LAV%, current smoking, and lower SDLAV independently contributed to an excessive decline in FEV1, whereas ratio of residual volume to total lung capacity, ratio of diffusing capacity to alveolar ventilation, and WA% did not, after adjusting for age, height, weight, and ratio of CTmeasured total lung volume to physiologicallymeasured total lung capacity. Conclusions:A more homogeneous distribution of emphysema contributed to an accelerated decline in FEV1 independently of baseline pulmonary function, wholelung emphysema severity, and smoking status. In addition to wholelung analysis of emphysema, CT assessment of the cranialcaudal distribution of emphysema might be useful for predicting rapid, progressive disease and for developing a targeted strategy with which to prevent disease progression. Keywords:Chronic obstructive pulmonary diseases, COPD, CT, Emphysema, Lung function, Heterogeneity
* Correspondence: smuro@kuhp.kyotou.ac.jp 1 Department of Respiratory Medicine, Graduate School of Medicine, Kyoto University, 53 Kawaharacho, Shogoin, Sakyoku, Kyoto 6068507, Japan Full list of author information is available at the end of the article
© 2012 Tanabe et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
  • Univers Univers
  • Ebooks Ebooks
  • Livres audio Livres audio
  • Presse Presse
  • Podcasts Podcasts
  • BD BD
  • Documents Documents